Organelle functions

 

 

Organelle Function - Mitochondrial Membrane Potential (mmp)

The mmp is due a differential distribution of proteins on either side of the impermeable inner mitochondrial membrane. In apoptosis,irrespective of the stimulus, loss of mmp occurs with the formation of mitochondrial permeability transition pore (PT) or mitochondrial megachannel.

The fall in mmp can be measured flow cytometrically with a range of dyes all of which alter there fluorescence intensity with any change in mmp. These dyes include the carbocyanine molecules DiOC6(3) and DiIC1(5). Other cationic lipophilic dyes include CMXRos, TMRE and rhodamine 123.

Organelle Function - Reactive Oxygen Species

Reactive oxygen species include super-oxide, hydrogen peroxide and nitric oxide which are generated in small amounts during oxidative phosphorylation. Cells undergoing oxidative stress generate increasing amounts of superoxide and hydrogen peroxide.

There are numerous dyes available such as H2CFDA which are analogues of fluoroscein and dihydrogenated molecules of rhodamine 123 and Calcien AM that preferentially detect hydrogen peroxide.

Superoxide is preferentially detected by dihydroethidium

 